FM200 Fire System for Electrical Control Room and Power Distribution Room Fire Protection

Still deciding? Get samples of $ !
Order Sample

Product Description

i

Basic Information

Model NO. FM200 Fire System Object Class A/B/C/D/E Fire
Certification CCC, ISO9001 Retirement Life 8 Years
Agent Type FM200 / HFC-227ea / FK-5112 Power Source Gas Fire Extinguisher
Filling Pressure 2.5MPa / 4.2MPa / 5.6MPa Capacity Customized One-to-One
HS Code 84241000 Origin China

Product Description

Clean Agent Automatic Fire Suppression System

The FM200 (HFC-227ea) and NOVEC 1230 / FK5112 suppression systems are advanced clean agent solutions designed in accordance with NFPA 2001 standards. These systems provide fast, reliable, and residue-free fire protection, making them ideal for environments where water-based systems could damage sensitive equipment.

Fire System 1
Fire System 2

System Operation

When set to "auto" mode, the system is controlled by smoke and temperature detectors. Upon detecting a fire signal, the control device logic triggers sound and light alarms, closes linkage devices, and after a brief delay, releases the extinguishing agent to suppress the fire rapidly.

Operation Diagram

Key Advantages

  • Clean Agent Technology – No residue, no secondary damage
  • Fast Discharge – Fire suppression within seconds
  • Safe for Occupied Spaces – Designed for human presence
  • Non-Conductive – Ideal for electrical and electronic equipment
  • Compact Design – Space-saving cylinder options
  • Low Maintenance – Long service life and stable performance
Unit Vertical 1
Unit Vertical 2

Technical Specifications

Parameter Technical Detail (4.2Mpa) Technical Detail (5.6Mpa)
Spraying Time ≤ 10 Seconds
Max Single-Zone Area 800 m²
Max Single-Zone Volume 3600 m³
Filling Density ≤ 950 kg/m³ ≤ 1080 kg/m³
Power Source DC24V / 1.6A
Cylinder Capacity Options 16L to 500L (Various sizes available)
Cylinder Option 1
Cylinder Option 2
Cylinder Option 3

Applications

Our fire suppression systems are designed for high-value environments:

  • Data Centers & Server Rooms: Protection for IT infrastructure without water damage.
  • Archives & Museums: Safeguarding valuable documents and artwork.
  • Labs & Medical Facilities: Protecting precision instruments and chemicals.
  • Control Rooms: Preventing damage to PLC cabinets and electronics.
  • Power Facilities: Used in substations, generator rooms, and UPS rooms.
Application 1

Production & Packing

Production Process
Packing
?

Frequently Asked Questions

Q1: What is the difference between FM200 and NOVEC 1230 systems?
FM200 uses HFC227ea agent, while NOVEC 1230 uses FK5112. NOVEC 1230 generally has a lower environmental impact, while FM200 is widely recognized for its cost-effectiveness.
Q2: Is the suppression system safe for people in the room?
Yes. When properly designed and installed according to safety standards, both FM200 and NOVEC 1230 systems are safe for occupied spaces.
Q3: Can the system be customized for specific room sizes?
Absolutely. Cylinder capacity, piping network, and nozzle layouts are tailored based on the specific room volume and the identified fire risks.
Q4: Is this system suitable for data centers and server rooms?
Yes, clean agent fire suppression systems are the industry standard for data centers and IT rooms as they leave no residue and are non-conductive.
Q5: What working pressure options are available?
We offer cylinders with working pressures of 4.2MPa, 5.6MPa, and 8.0MPa to allow for flexible system design depending on piping distance and room size.
Q6: Do you provide design and technical documents?
Yes, we provide comprehensive technical support including system layout drawings, piping distribution diagrams, and wiring schematics.

Related Products